What Are CO2e and GWP? A Practical Guide for Manufacturers
Date: 24/11/2026
Why did our carbon number jump after one air-conditioning service?
Most factories start their carbon calculations with electricity and fuel. Those numbers are easy to find because they come from utility bills, fuel receipts and meter readings.
Some of the largest items in a factory's direct emissions, however, never appear on a bill. Refrigerant top-ups, SF6 in high-voltage switchgear and methane from wastewater treatment usually sit in contractor service reports and maintenance logs.
To compare these gases with carbon dioxide, carbon accounting uses two ideas: CO2e and GWP. This guide explains what they mean, which values to use and how to capture the data in a Malaysian factory.
In This Article
What CO2e Means
CO2e, or carbon dioxide equivalent, is a common unit that expresses different greenhouse gases as the amount of carbon dioxide that would cause the same warming. It lets a company add all its gases into one figure for a site, a business or a product.
Carbon accounting covers seven gases or gas groups: carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), hydrofluorocarbons (HFCs), perfluorocarbons (PFCs), sulphur hexafluoride (SF6) and nitrogen trifluoride (NF3). Reports prepared under the GHG Protocol, ISO 14064-1, ISO 14067 and IFRS S2, the basis of Malaysia's National Sustainability Reporting Framework, all state results in CO2e.
What GWP Means
GWP, or global warming potential, measures how much heat a gas traps over a set period compared with the same mass of carbon dioxide. Carbon accounting normally uses the 100-year value, written as GWP-100. Carbon dioxide has a GWP of 1 by definition.
The conversion is simple: mass of gas in kg × GWP = kg CO2e.
Gas and Typical Factory Source | GWP-100 (AR6) |
Carbon dioxide (fuel combustion) | 1 |
Methane (wastewater treatment, biogas, gas leaks) | 27.0 to 29.8 |
Nitrous oxide (combustion, some chemical processes) | 273 |
HFC-32 or R-32 (newer split air-conditioners) | 771 |
HFC-134a or R-134a (chillers, vehicle air-conditioning) | 1,530 |
R-410A (air-conditioners and heat pumps) | About 2,256 |
Nitrogen trifluoride (electronics and semiconductor manufacturing) | 17,400 |
Sulphur hexafluoride (high-voltage switchgear) | 24,300 |
Values are from the GHG Protocol's table of IPCC AR6 values. Methane has separate fossil and non-fossil values. R-410A is a 50:50 blend of HFC-32 and HFC-125, so its value is calculated from those two gases.
Why Small Leaks Matter
Because many of these gases have high GWP values, a few kilograms can move a factory's total more than people expect.

Example: A contractor tops up 5 kg of R-410A during an air-conditioning service. 5 kg × 2,256 = 11,280 kg CO2e, or about 11.3 tonnes. Using Peninsular Malaysia's 2024 grid emission factor of 0.740 kg CO2e per kWh, that is roughly the same as the emissions from 15,200 kWh of electricity.
These emissions belong in Scope 1, as explained in our guide to Scope 1, 2 and 3 emissions. They also flow into any Product Carbon Footprint built on site data, so a missing refrigerant record can understate both.
Which GWP Values to Use
The Intergovernmental Panel on Climate Change (IPCC) publishes GWP values in its assessment reports and updates them as the science improves. The most common sets are AR5, published in 2014, and AR6, published in 2021. The GHG Protocol's GWP table, updated in August 2024, recommends AR6.
Gas | AR5 → AR6 |
Methane (fossil) | 30 → 29.8 |
Nitrous oxide | 265 → 273 |
HFC-32 | 677 → 771 |
HFC-134a | 1,300 → 1,530 |
Sulphur hexafluoride | 23,500 → 24,300 |
Mixing versions in one report, or comparing a result based on AR5 with a later one based on AR6, can create a change that has nothing to do with real performance. Some customers and reporting frameworks name the version they expect, so check the requirement and always state which version you used.
Note: Emission factors that are already given in CO2e, such as grid electricity factors, have a GWP basis built in. Our guide to emission factors explains why that basis should be recorded.
What It Means for Malaysia
In Malaysian factories, refrigerants are usually the largest non-CO2 source. Air-conditioning runs all year, and many plants also use chillers, cold rooms and process cooling.
Malaysia ratified the Kigali Amendment to the Montreal Protocol in October 2020. Under it, the country's HFC consumption has been frozen at its baseline level since 01/01/2024, and an 80% reduction is required by 2045. Over time, this is likely to push equipment towards lower-GWP refrigerants.
Non-CO2 gases also appear in supplier carbon questionnaires and PCF requests from multinational customers. ISO 14067 and the GHG Protocol cover all greenhouse gases, not only carbon dioxide, so customer-facing carbon data is expected to include them.
How to Capture the Data

Step 1: List Your Non-CO2 Sources
Walk the site and list air-conditioners, chillers, cold rooms, switchgear, fire suppression systems, wastewater treatment and any process gases. Record the gas type and charge size of each unit from its nameplate.
Step 2: Assign Ownership
Decide who collects the data, usually the facilities or maintenance team, and how often it is updated.
Step 3: Change the Contractor Template
Ask service contractors to state the gas type and the quantity added in kg on every service report, not only "gas top-up done".
Step 4: Convert with One GWP Set
Multiply each quantity by GWP-100 values from one IPCC report, ideally AR6, and use the same set across your organisation's figures and product calculations.
Step 5: Keep the Evidence
File service reports, gas purchase invoices and equipment nameplate photos so that customers or verifiers can check the figures.
Common Mistakes to Avoid
1. Counting Only Electricity and Fuel
Leaving out refrigerants, SF6 and wastewater methane understates Scope 1, sometimes by a large margin.
2. Recording Ringgit Instead of Kilograms
Invoices often show the cost of a gas top-up. The calculation needs the mass of gas in kg.
3. Using the Wrong Refrigerant Type
R-410A has roughly three times the GWP of R-32. Check the equipment nameplate rather than assuming.
4. Mixing GWP Versions
Using AR5 values in one report and AR6 in another makes year-on-year comparisons unreliable.
5. Counting the Full Charge Instead of the Top-Up
The emission is the gas that escaped, which is usually estimated from the amount refilled, not the total charge held in the equipment.
How Kalyx ESG Academy Can Help
Kalyx ESG Academy helps Malaysian manufacturers build practical carbon data systems, from identifying emission sources and setting up data templates to calculating Scope 1, 2 and 3 emissions and Product Carbon Footprint with consistent methods.
If your carbon figures so far cover only electricity and fuel, talk to Kalyx ESG Academy to review what may be missing.
Sources:
Global Warming Potential Values (AR6), GHG Protocol, 07/08/2024
Use of HFC Fridge, Air-Con Gas to Be Phased Out from 2024, Free Malaysia Today, 08/11/2020
Grid Emission Factor (GEF) in Malaysia, 2022–2024 (Provisional), Energy Commission, 23/02/2026
IFRS S2 Climate-related Disclosures, IFRS Foundation
This article is for general information only and does not constitute professional or legal advice. Requirements may change; please check the latest official guidance or speak to a qualified adviser for your specific situation.